z-logo
open-access-imgOpen Access
Application of a High Throughput Method of Biomarker Discovery to Improvement of the EarlyCDT®-Lung Test
Author(s) -
Isabel Macdonald,
Andrea Murray,
Graham Healey,
Celine B. Parsy-Kowalska,
Jared Allen,
Jane McElveen,
Chris Robertson,
H. F. Sewell,
Caroline Chapman,
J.F.R. Robertson
Publication year - 2012
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0051002
Subject(s) - lung cancer , autoantibody , medicine , biomarker , lung cancer screening , lung , oncology , pathology , immunology , antibody , biology , biochemistry
Background The National Lung Screening Trial showed that CT screening for lung cancer led to a 20% reduction in mortality. However, CT screening has a number of disadvantages including low specificity. A validated autoantibody assay is available commercially ( Early CDT®-Lung) to aid in the early detection of lung cancer and risk stratification in patients with pulmonary nodules detected by CT. Recent advances in high throughput (HTP) cloning and expression methods have been developed into a discovery pipeline to identify biomarkers that detect autoantibodies. The aim of this study was to demonstrate the successful clinical application of this strategy to add to the Early CDT-Lung panel in order to improve its sensitivity and specificity (and hence positive predictive value, (PPV)). Methods and Findings Serum from two matched independent cohorts of lung cancer patients were used (n = 100 and n = 165). Sixty nine proteins were initially screened on an abridged HTP version of the autoantibody ELISA using protein prepared on small scale by a HTP expression and purification screen. Promising leads were produced in shake flask culture and tested on the full assay. These results were analyzed in combination with those from the Early CDT-Lung panel in order to provide a set of re-optimized cut-offs. Five proteins that still displayed cancer/normal differentiation were tested for reproducibility and validation on a second batch of protein and a separate patient cohort. Addition of these proteins resulted in an improvement in the sensitivity and specificity of the test from 38% and 86% to 49% and 93% respectively (PPV improvement from 1 in 16 to 1 in 7). Conclusion This is a practical example of the value of investing resources to develop a HTP technology. Such technology may lead to improvement in the clinical utility of the Early CDT-Lung test, and so further aid the early detection of lung cancer.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom