Evaluation of Interferon-Gamma Release Assays in the Diagnosis of Recent Tuberculosis Infection in Health Care Workers
Author(s) -
Irma Casas,
Irene Latorre,
María Esteve,
Juan RuizManzano,
Dora Rodríguez,
Cristina Prat,
Ignasi García-Olivé,
Alícia Lacoma,
V. Ausina,
José Domínguez
Publication year - 2009
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0006686
Subject(s) - medicine , latent tuberculosis , tuberculin , concordance , tuberculosis , interferon gamma , tuberculosis diagnosis , interferon gamma release assay , quantiferon , immunology , mycobacterium tuberculosis , pathology , cytokine
Background Health care workers (HCWs) are a group at risk of latent tuberculosis infection (LTBI). The aims of this study were to determine IFN-γ response by Quanti FERON -TB GOLD In Tube (QFN-G-IT) and T-SPOT.TB in HCWs, comparing the results with tuberculin skin test (TST); and to analyze the capacity of IFN-γ tests to detect recent versus remote LTBI with a prolonged stimulation test (PST). Methodology/Principal Findings A total of 147 HCWs were enrolled; 23 of whom were BCG vaccinated. 95 HCWs (64.6%) had a previous positive TST and were not retested; and 52 HCWs had a previous negative TST or were tested for the first time. When we analysed individuals without previous positive TST, the number of positive results for T-SPOT.TB was 12/52 (23.1%); and for QFN-G-IT, 9/52 (17.3%). The global concordance (κ) between T-SPOT.TB and QFN-G-IT with TST was 0.754 and 0.929 respectively. Of individuals with previous positive TST, T-SPOT.TB and QFN-G-IT were negative in 51.6% (49/95) and 62.1% (59/95) respectively, decreasing the concordance to 0.321 and 0.288, respectively. In non-BCG vaccinated HCWs with previous positive TST a positive IFN-γ test was associated with degree of exposure and diameter of TST. PST was performed in 24 HCW with previous positive TST and negative IFN-γ tests. PST was developed in 3 cell cultures stimulated with medium alone, ESAT-6 and CFP-10, respectively. In the third and sixth day of incubation period, part of the supernatants were replaced with complete medium supplemented with (rIL)-2. On day 9, ELISPOT assay was performed. In 14 samples PST was not valid due to not having enough cells. In 8 cases, the response was negative, and in 2 cases positive, suggesting that these patients were infected with Mycobacterium tuberculosis in some point in the past. Conclusions Both IFN-γ tests showed a similar number of positive results, and concordance between the tests was excellent. None of the tests was affected by prior BCG vaccination. IFN-γ tests are a useful tool for detecting recent infection in HCW population.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom