z-logo
open-access-imgOpen Access
Passive component based multifunctional Jones matrix swept source optical coherence tomography for Doppler and polarization imaging
Author(s) -
Yiheng Lim,
Young-Joo Hong,
Lian Duan,
Masahiro Yamanari,
Yoshiaki Yasuno
Publication year - 2012
Publication title -
optics letters
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.524
H-Index - 272
eISSN - 1071-2763
pISSN - 0146-9592
DOI - 10.1364/ol.37.001958
Subject(s) - optical coherence tomography , optics , polarization (electrochemistry) , birefringence , orthogonal polarization spectral imaging , doppler effect , multiplexing , physics , materials science , laser , computer science , telecommunications , chemistry , astronomy
We present a fiber based multifunctional Jones matrix swept source optical coherence tomography (SS-OCT) system for Doppler and polarization imaging. Jones matrix measurement without using active components such as electro-optic modulators is realized by incident polarization multiplexing based on independent delay of two orthogonal polarization states and polarization diversity detection. In addition to polarization sensitivity, this system measures Doppler flow without extra hardware for phase stabilized SS-OCT detection. An eighth-wave plate was measured to demonstrate the polarization detection accuracy. The optic nerve head of a retina was measured in vivo. Detailed vasculature and birefringent structures were investigated simultaneously.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom