z-logo
open-access-imgOpen Access
Measurement variability associated with KXRF bone lead measurement in young adults.
Author(s) -
Jane A. Hoppin,
Antonio Aro,
Howard Hu,
P. Barry Ryan
Publication year - 2000
Publication title -
environmental health perspectives
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.257
H-Index - 282
eISSN - 1552-9924
pISSN - 0091-6765
DOI - 10.1289/ehp.00108239
Subject(s) - bone mineral , tibia , lead (geology) , medicine , zoology , dentistry , nuclear medicine , anatomy , osteoporosis , biology , paleontology
In vivo bone lead measurement using K X-ray fluorescence (KXRF) has been used to estimate long-term lead exposure, especially in adults. Relatively few studies have been conducted on young subjects with this technique. To explore the measurement variability of KXRF bone lead measurements in young subjects, the tibiae of two male cadavers from Boston, Massachusetts, 17 and 20 years of age, were obtained for repeated bone lead measurements. Bone lead concentrations were measured using a grid of nine locations, 1 cm apart, centered at the midpoint of the tibia. Each location was sampled using five 60-min measurements. Measured concentrations ranged from < 0 to 11.8 microg Pb/g bone mineral across a tibia with mean concentrations for the midpoint locations of 0.8 microg Pb/g bone mineral SD = 2.5 and 2.0 microg Pb/g bone mineral (SD = 1.9) for the left and right legs of the younger subject and 3.6 microg Pb/g bone mineral (SD = 2.6) and 6.0 microg Pb/g bone mineral (SD = 3.3) for the left and right legs of the older subject. Although bone lead concentrations did not vary significantly by measurement location in an individual leg, reported measurement uncertainty increased significantly at locations that were 1 cm from the center of the tibia horizontally (p < 0.0001). Symmetry in bone lead concentration between legs was observed for the 17-year-old subject. Potential asymmetry between the left and right legs was suggested for the 20-year-old subject (p = 0.06). These data describe the degree of variability that may be associated with bone lead measurements of young subjects with low bone lead concentrations using a standard spot-source KXRF instrument. Because of the importance of conducting additional research on adolescent lead toxicity, further improvements to the precision of KXRF measurement are needed.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom