z-logo
open-access-imgOpen Access
A Single-Center Observational Clinical Study on Factors Associated with Regional Cerebral Oxygen Saturation in Full-Term Newborn Infants During Birth Transition
Author(s) -
Weiqiao Zhang,
Fei Ge,
Chaohui Lian,
Ruiqiang Xia,
Bing Zhang
Publication year - 2021
Publication title -
medical science monitor
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.636
H-Index - 85
eISSN - 1643-3750
pISSN - 1234-1010
DOI - 10.12659/msm.928750
Subject(s) - medicine , oxygen saturation , anesthesia , pulse oximetry , gestational age , intraventricular hemorrhage , obstetrics , pediatrics , oxygen , pregnancy , chemistry , organic chemistry , biology , genetics
Background Hypoxic hypoperfusion injury in the brain is a cause of potential injury and even death in the growth period of newborns. Therefore, monitoring regional cerebral oxygen saturation (CrSO2) during this period is particularly important. This observational clinical study from a single center aimed to investigate the factors associated with CrSO2 in full-term newborn infants during birth transition. Material/Methods We enrolled 84 full-term newborn infants delivered by cesarean section. We started the stopwatch with the obstetrician clamping the newborns’ umbilical cords and recorded the values of newborns’ CrSO2, pulse oxygen saturation (SpO2), pulse rate (PR), end-tidal carbon dioxide (EtCO2), and respiratory rate (RR) at 2 min, 5 min, and 10 min. We weighed the newborns before they left the operating room and used statistical methods to compare the correlation between each observation factor. Results Pearson correlation coefficients between CrSO2 and SpO2 measured at 2 min, 5 min, and 10 min were 0.491, 0.599, and 0.587, respectively (P<0.01). Pearson correlation coefficients between CrSO2 and EtCO2 measured at 2 min, 5 min, and 10 min were −0.304, −0.443, and −0.243, respectively (P<0.05). Regardless of a newborn’s weight, PR, or RR, the correlation between any of those factors and the value of CrSO2 measured at the corresponding time point had no significance (P>0.05). Conclusions This study showed a correlation between CrSO2 and SpO2 and CrSO2 and EtCO2 during birth transition of full-term infants delivered by elective cesarean section, but CrSO2 had no significant correlation with neonatal weight, PR, or RR.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom