z-logo
open-access-imgOpen Access
The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
Author(s) -
Fengchao Zhao,
Zheng Li,
Qi Cheng,
Weifan Hu,
Bailiang Wang
Publication year - 2020
Publication title -
medical science monitor
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.636
H-Index - 85
eISSN - 1643-3750
pISSN - 1234-1010
DOI - 10.12659/msm.921459
Subject(s) - tantalum , radiodensity , medicine , surgery , blood loss , osteolysis , implant , total hip arthroplasty , femoral head , arthroplasty , radiography , materials science , metallurgy
BACKGROUND The failure of porous tantalum rods applied to patients with osteonecrosis of the femoral head (ONFH) has been increasingly reported during the last few years. Very few studies have reported methods for implant removal. This study aimed at comparing 2 procedures used for the removal of a failed tantalum rod during conversion to total hip arthroplasty (THA). MATERIAL AND METHODS A total of 65 patients (65 hips), who underwent THA after failed implantation of a tantalum rod between June 2007 and December 2016, were retrospectively evaluated. These patients were classified into 2 groups depending on whether the antegrade approach (removal of the tantalum rod from the tip to the butt at the lateral femoral cortex, n=27) or retrograde approach (removal of the tantalum rod from the butt at the lateral femoral cortex to the proximal tip, n=38) was used for rod extraction. These 2 groups were compared for incision length, operation time, blood loss, fracture, tantalum debris, Harris hip scores, and the presence of osteolysis and/or radiolucency. RESULTS These 2 groups did not present any significant differences in terms of Harris hip score and incision length. However, the operation time (P=0.000), blood loss (P=0.000), amount of tantalum debris (P=0.000), and presence of radiolucency (P=0.046) were greater for the retrograde approach than for the antegrade approach. CONCLUSIONS The risk of conversion to THA following failed tantalum rod implantation is high. In such cases, the antegrade procedure was found to be a simple and efficient method for removing the trabecular metal rod with the use of a trephine.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom