Alarm Settings of Continuous Glucose Monitoring Systems and Associations to Glucose Outcomes in Type 1 Diabetes
Author(s) -
Yu Kuei Lin,
Danielle Groat,
Owen Chan,
Man Hung,
Anu Sharma,
Michael W. Varner,
Ramkiran Gouripeddi,
Julio C. Facelli,
Simon J. Fisher
Publication year - 2019
Publication title -
journal of the endocrine society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.046
H-Index - 20
ISSN - 2472-1972
DOI - 10.1210/jendso/bvz005
Subject(s) - hypoglycemia , continuous glucose monitoring , alarm , medicine , context (archaeology) , diabetes mellitus , type 1 diabetes , plasma glucose , endocrinology , type 2 diabetes , biology , paleontology , materials science , composite material
Context Little evidence exists regarding the positive and negative impacts of continuous glucose monitor system (CGM) alarm settings for diabetes control in patients with type 1 diabetes (T1D). Objective Evaluate the associations between CGM alarm settings and glucose outcomes. Design and Setting A cross-sectional observational study in a single academic institution. Patients and Main Outcome Measures CGM alarm settings and 2-week CGM glucose information were collected from 95 T1D patients with > 3 months of CGM use and ≥ 86% active usage time. The associations between CGM alarm settings and glucose outcomes were analyzed. Results Higher glucose thresholds for hypoglycemia alarms (ie, ≥ 73 mg/dL vs < 73 mg/dL) were related to 51% and 65% less time with glucose < 70 and < 54 mg/dL, respectively (P = 0.005; P = 0.016), higher average glucose levels (P = 0.002) and less time-in-range (P = 0.005), but not more hypoglycemia alarms. The optimal alarm threshold for < 1% of time in hypoglycemia was 75 mg/dL. Lower glucose thresholds for hyperglycemia alarms (ie, ≤ 205 mg/dL vs > 205 mg/dL) were related to lower average glucose levels and 42% and 61% less time with glucose > 250 and > 320 mg/dL (P = 0.020, P = 0.016, P = 0.007, respectively), without more hypoglycemia. Lower alarm thresholds were also associated with more alarms (P < 0.0001). The optimal alarm threshold for < 5% of time in hyperglycemia and hemoglobin A1c ≤ 7% was 170 mg/dL. Conclusions Different CGM glucose thresholds for hypo/hyperglycemia alarms are associated with various hypo/hyperglycemic outcomes. Configurations to the hypo/hyperglycemia alarm thresholds could be considered as an intervention to achieve therapeutic goals.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom