z-logo
open-access-imgOpen Access
Point-of-care capillary HbA1c measurement in the emergency department: a useful tool to detect unrecognized and uncontrolled diabetes
Author(s) -
Fernando Gómez-Peralta,
Cristina Abreu,
Leonor Andreu-Urioste,
Ana Cristina Antolí,
Carmen Rico-Fontsaré,
David Martín-Fernández,
Rosa Resina-Rufes,
Juan Jesús Pérez-García,
Ángela Negrete-Muñoz,
Daniel Muñoz-Álvarez,
Guillermo E. Umpierrez
Publication year - 2016
Publication title -
international journal of emergency medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.53
H-Index - 29
eISSN - 1865-1380
pISSN - 1865-1372
DOI - 10.1186/s12245-016-0107-6
Subject(s) - medicine , diabetes mellitus , emergency department , observational study , emergency medicine , prospective cohort study , point of care , angiology , endocrinology , pathology , psychiatry
Background Inpatient hyperglycaemia and diabetes mellitus (DM) are common and are associated with an increased risk of complications and mortality. The severity of hyperglycaemia determines the rate of complications in patients treated in the emergency department (ED). Our aim was to examine whether determination of the capillary haemoglobin A1c (HbA1c) is a reliable method for detecting unknown diabetes and poor glycaemic control in the ED. Methods A prospective observational study was conducted in adult (>18 years) patients treated in a single-centre ED. We compared the results of HbA1c levels measured by Bio-Rad in2it point-of-care device on a capillary blood sample and by the hospital laboratory. Results A total of 187 ED patients with an average age of 57.1 ± 19.2 years were studied. The mean HbA1c value was 5.78 ± 1.26 % by capillary POC testing and 6.10 ± 1.12 % by the hospital laboratory (correlation = 0.712, P  < 0.001). A total of 17.1 % of cases had a prior diagnosis of DM . The diagnosis of DM (plasma glucose > 126 mg/dL and/or HbA1c > 6.5 %) was made in ten (5.4 %) additional cases ( prior undiagnosed DM ) for a total prior DM prevalence of 22.5 % (95 % CI 16.4–28.5 %). Capillary HbA1c detected 11 additional cases of unknown DM (5.9 %). A capillary HbA1c value greater than 6 % has a sensitivity of 85.7 % and specificity of 85.3 % for the screening of DM. Conclusions Determination of the capillary HbA1c in the ED is a reliable, fast, and simple system for the screening of unknown or uncontrolled DM.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom