z-logo
open-access-imgOpen Access
A prospective cohort study of the long-term effects of CPAP on carotid artery intima-media thickness in Obstructive sleep apnea syndrome
Author(s) -
David S. Hui,
Qing Shang,
Fanny W.S. Ko,
Susanna S.S. Ng,
CheukChun Szeto,
Jenny Ngai,
Alvin Tung,
Ka–Fai To,
Terence Chan,
CheukMan Yu
Publication year - 2012
Publication title -
respiratory research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.846
H-Index - 104
eISSN - 1465-993X
pISSN - 1465-9921
DOI - 10.1186/1465-9921-13-22
Subject(s) - medicine , obstructive sleep apnea , prospective cohort study , intima media thickness , common carotid artery , continuous positive airway pressure , carotid arteries , cardiology
Objective To examine the long-term effect of CPAP on carotid artery intima-media thickness (IMT) in patients with Obstructive sleep apnea syndrome(OSAS). Methods A prospective observational study over 12 months at a teaching hospital on 50 patients newly diagnosed with OSAS who received CPAP or conservative treatment (CT). Carotid IMT was assessed with B-mode Doppler ultrasound from both carotid arteries using images of the far wall of the distal 10 mm of the common carotid arteries at baseline, 6 months and 12 months. Measurements and results [mean (SE)] Altogether 28 and 22 patients received CPAP and CT respectively without significant differences in age 48.8(1.8) vs 50.5(2.0)yrs, BMI 28.2(0.7) vs 28.0(1.2)kg/m2, ESS 13.1(0.7) vs 12.7(0.6), AHI 38(3) vs 39(3)/hr, arousal index 29(2) vs 29(2)/hr, minimum SaO 2 75(2) vs 77(2)% and existing co-morbidities. CPAP usage was 4.6(0.3) and 4.7(0.4)hrs/night over 6 months and 1 year respectively. Carotid artery IMT at baseline, 6 months, and 12 months were 758(30), 721(20), and 705(20)micron for the CPAP group versus 760(30), 770(30), and 778(30)micron respectively for the CT group, p = 0.002. Among those free of cardiovascular disease(n = 24), the carotid artery IMT at baseline, 6 months and 12 months were 722(40), 691(40), and 659(30)micron for the CPAP group (n = 12) with usage 4.5(0.7) and 4.7(0.7) hrs/night over 6 months and 12 months whereas the IMT data for the CT group(n = 12) were 660(20), 685(10), and 690(20)micron respectively, p = 0.006. Conclusions Reduction of carotid artery IMT occurred mostly in the first 6 months and was sustained at 12 months in patients with reasonable CPAP compliance.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here