z-logo
open-access-imgOpen Access
Elimination of myeloma cells from bone marrow by using monoclonal antibodies and magnetic immunobeads
Author(s) -
Chihiro Shimazaki,
David Wisniewski,
DA Scheinberg,
Jens Atzpodien,
A Strife,
Subhash C. Gulati,
Jerrold Fried,
Rosanne Wisniewolski,
Wang Cy,
BD Clarkson
Publication year - 1988
Publication title -
blood
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.515
H-Index - 465
eISSN - 1528-0020
pISSN - 0006-4971
DOI - 10.1182/blood.v72.4.1248.1248
Subject(s) - bone marrow , multiple myeloma , monoclonal antibody , antibody , haematopoiesis , immunomagnetic separation , progenitor cell , microbiology and biotechnology , monoclonal , medicine , cancer research , chemistry , immunology , stem cell , biology , genetics
The efficacy of immunomagnetic beads to purge human myeloma cells from bone marrow ex vivo was evaluated. The optimal conditions for purging were studied first by using three myeloma cell lines: RPMI-8226, SKO-007, and SKMM-2. Myeloma cells labeled with the vital fluorescent dye Hoechst 33342 were admixed with normal bone marrow cells, and two monoclonal antibodies reactive with the myeloma cells (PCA-1 and BL-3) were added alone or in combination with the cells. Magnetic beads coated with goat antimouse immunoglobulin G were then added, and the tumor cells to which beads were attached were separated from the mixture with a magnet. The efficacy of tumor cell removal was dependent on the bead-to-tumor ratio; a ratio of more than 500 was optimal in the presence of excess normal marrow cells. The combination of monoclonal antibodies PCA-1 and BL-3 increased the tumor cell removal as compared with either antibody alone. Two cycles of treatment were more effective than one cycle was. Under optimal conditions, 2.3 to 4 logs of tumor cells could be removed from the mixture containing 10% myeloma cells without a significant loss of normal hematopoietic progenitors as measured by CFU-GM, CFU-GEM, and BFU-E. When the efficacy of this procedure was tested on fresh bone marrow from patients with multiple myeloma (MM) by using the combination of PCA-1, BL-3, and J-5, 1.6 to 2.5 logs of tumor cells could be removed by one cycle of treatment, even from marrows containing less than 10% myeloma cells. These observations support the use of monoclonal antibody combinations and immunobeads as a reliable and nontoxic method to eliminate contaminating myeloma cells ex vivo in preparation for autologous bone marrow transplantation in patients with MM.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom