Improving Laboratory Efficiency by Automation of Preanalytic Processing of ThinPrep Specimens for Real-Time PCR High-Risk HPV Testing
Author(s) -
Daniela Barbieri,
Simona Venturoli,
Silvano Costa,
Maria Paola Landini
Publication year - 2015
Publication title -
slas technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.714
H-Index - 16
eISSN - 2472-6311
pISSN - 2472-6303
DOI - 10.1177/2211068215569347
Subject(s) - computer science , reproducibility , laboratory automation , concordance , vial , sample (material) , spotting , protocol (science) , repeatability , automated method , automation , medicine , chromatography , pathology , artificial intelligence , engineering , chemistry , mechanical engineering , alternative medicine
Cervical specimens collected in liquid-based cytology (LBC) media are the most common sample type used for high-risk human papillomavirus (HPV) testing. Since preanalytic steps such as vortexing and decapping vials, liquid transfer to a sample input tube with matching unique identifier, and recapping the original vials are required for processing LBC samples prior to running the Abbott RealTime High Risk HPV assay (Abbott, Wiesbaden, Germany), a full manual execution can be complicated, especially in high-throughput diagnostic contexts. Here, a custom-configured worktable setup for the Tecan Freedom EVO (Tecan, Männedorf, Switzerland) designed to automate and control preanalytic steps for ThinPrep (Hologic, Marlborough, MA) samples was used to evaluate the impact of automated versus manual preanalytics. Archival results for manual processing of 226 samples were compared with those obtained with the Tecan protocol, observing a very good overall concordance for final assay interpretation (95.6%). High overall agreement (100%) resulted also from retesting 99 samples by both the preanalytical protocols. High reproducibility was observed analyzing 23 randomly selected samples by automated preprocessing in triplicate. Hence, the new configuration of the Tecan platform translates the manual steps required to process ThinPrep specimens into automated operations, controls sample identification, and allows for saving hands-on time, while maintaining assay reproducibility and ensuring reliability of results, making it suitable for screening settings.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom