z-logo
open-access-imgOpen Access
The Effects of Temperature and Relative Humidity on Point-of-Care Glucose Measurements in Hospital Practice in a Tropical Clinical Setting
Author(s) -
Busadee Pratumvinit,
Nattakom Charoenkoop,
Soamsiri Niwattisaiwong,
Gerald J. Kost,
Panutsaya Tientadakul
Publication year - 2016
Publication title -
journal of diabetes science and technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.039
H-Index - 75
eISSN - 1932-3107
pISSN - 1932-2968
DOI - 10.1177/1932296816633485
Subject(s) - relative humidity , medicine , zoology , plasma glucose , point of care , humidity , point of care testing , chemistry , surgery , insulin , immunology , biology , meteorology , nursing , physics
Background: Hospitals in tropical countries experience conditions that exceed manufacturer temperature and humidity limits for point-of-care (POC) glucose reagents. Our goal was to assess the effects of out-of-limits storage temperature, operating temperature, and operating humidity on POC glucose measurement reliability.Methods: Quality control measurements were performed monthly using glucose test strips stored under controlled conditions and in inpatient wards under ambient conditions. Glucose test strips were evaluated in groups organized by operating temperatures of 24-25 (group 1), 28-29 (group 2), and 33-34°C (group 3), and relative humidity (RH) of ≤70 (group A), ~80 (group B), and ~90% (group C).Results: Glucose results for different storage conditions were inconsistent. Measurements at higher operating temperatures had lower values with mean differences of −2.4 ( P < .001) and −36.5 ( P < .001) mg/dL (28-29 vs 24-25°C), and −3.6 ( P < .001) and −37.4 ( P < .001) mg/dL (33-34 vs 24-25°C) for low and high control levels, respectively. Measurements at higher RH had lower values with mean differences of −4.0 ( P < .001) and −13.2 ( P < .001) mg/dL (~80 vs ≤70% RH), and −5.8 ( P < .001) and −16.6 ( P < .001) mg/dL (~90 vs ≤70% RH) for low and high levels, respectively.Conclusions: High temperature and high RH decreased glucose concentrations for the POC oxidase-based system we evaluated. We recommend that individual hospitals perform stress testing, then determine if maximum absolute differences, which represent highest risk for patients, are clinically significant for decision making by using error grid analysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom