Comparison of the Sysmex XT-2000iV with microscopic differential counts of canine bone marrow
Author(s) -
Iris Pernecker,
Natali Bauer,
Sigrid Johannes,
Melanie Ginder,
Johannes H. Harleman,
Andreas Moritz
Publication year - 2017
Publication title -
journal of veterinary diagnostic investigation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.529
H-Index - 78
eISSN - 1943-4936
pISSN - 1040-6387
DOI - 10.1177/1040638717692011
Subject(s) - nucleated red blood cell , bone marrow , cytology , hematology analyzer , repeatability , pathology , nuclear medicine , medicine , andrology , biology , chemistry , chromatography , pregnancy , fetus , genetics
Canine bone marrow is frequently assessed in the advanced preclinical research environment. Automated analysis provides time savings and objectivity over the gold standard of microscopic (cytologic) evaluation. We compared the analysis of 90 canine bone marrow samples by the Sysmex XT-2000iV hematology analyzer (Sysmex Corp., Kobe, Japan) with cytologic evaluation. Gates for cell populations were created in the system’s WBC/BASO channel. Variables “total nucleated red blood cells” (total_NRBC), “poly- and orthochromatic nucleated red blood cells” (poly_orth_NRBC), “total neutrophils” (total_NEUT), “mature neutrophils” (mature_NEUT), and myeloid-to-erythroid (M:E) ratio were compared with cytologic evaluation. Intra-assay repeatability and total error (TE) were calculated for both methods. Intra-assay repeatability was 0.95–2.48% for the XT-2000iV and 8.32–23.23% for cytology. Observed TE for the automated measurement was 5.16–46.8% and for cytology 22.70–76.74%. Spearman rank correlation was excellent for M:E ratio (0.91) and fair for the other populations (0.65–0.71). Absolute bias for M:E ratio was low (−0.114). A negative absolute bias of −7.71% for the XT-2000iV was found for poly_orth_NRBC, whereas the bias was positive for total_NEUT (7.10%) and mature_NEUT (14.67%). M:E ratio of canine bone marrow samples can be precisely determined using the Sysmex XT-2000iV WBC/BASO channel. Total_NRBC, poly_orth_NRBC, total_NEUT, and mature_NEUT can be estimated rapidly. With distinctly lower coefficient of variation and observed TE compared with cytology, automated measurement provides advantages in terms of standardization, and it is suited to the advanced preclinical research environment where large numbers of samples are investigated.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom