z-logo
open-access-imgOpen Access
Comparison of fibre‐optic‐guided endotracheal intubation through a supraglottic airway device versus hyperangulated video laryngoscopy by emergency physicians: A randomised controlled study in cadavers
Author(s) -
Groombridge Christopher J,
Maini Amit,
Mathew Joseph,
Fritz Peter,
Kim Yesul,
Fitzgerald Mark,
Smit De Villiers,
O'Reilly Gerard
Publication year - 2023
Publication title -
hong kong journal of emergency medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.145
H-Index - 12
eISSN - 2309-5407
pISSN - 1024-9079
DOI - 10.1177/10249079211034272
Subject(s) - medicine , airway , intubation , laryngoscopy , anesthesia , airway management , tracheal intubation , confidence interval , emergency department , population , surgery , nursing , environmental health
Background: After failed endotracheal intubation, using direct laryngoscopy, rescued using a supraglottic airway device, the choice of subsequent method to secure a definitive airway is not clearly determined. Objective: The aim of this study was to compare the time to intubation using a fibre‐optic airway scope, to guide an endotracheal tube through the supraglottic airway device, with a more conventional approach using a hyperangulated video laryngoscope. Methods: A single‐centre randomised controlled trial was undertaken. The population studied were emergency physicians working in an adult major trauma centre. The intervention was intubation through a supraglottic airway device guided by a fibre‐optic airway scope. The comparison was intubation using a hyperangulated video laryngoscope. The primary outcome was time to intubation. The trial was registered with ANZCTR.org.au (ACTRN12621000018819). Results: Four emergency physicians completed intubations using both of the two airway devices on four cadavers for a total of 32 experiments. The mean time to intubation was 14.0 s (95% confidence interval = 11.1–16.8) in the hyperangulated video laryngoscope group compared with 29.2 s (95% confidence interval = 20.7–37.7) in the fibre‐optic airway scope group; a difference of 15.2 s (95% confidence interval = 8.7–21.7, p  < 0.001). All intubations were completed within 2 min, and there were no equipment failures or evidence of airway trauma. Conclusion: Successful intubation of the trachea without airway trauma by emergency physicians in cadavers is achievable by either fibre‐optic airway scope via a supraglottic airway device or hyperangulated video laryngoscope. Hyperangulated video laryngoscope was statistically but arguably not clinically significantly faster than fibre‐optic airway scope via supraglottic airway device.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here