z-logo
open-access-imgOpen Access
Accuracy of the estimation of V and the implications this has when applying K t / V urea for measuring dialysis dose in peritoneal dialysis
Author(s) -
Davies Simon J,
Finkelstein Fredric O
Publication year - 2020
Publication title -
peritoneal dialysis international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.79
H-Index - 83
eISSN - 1718-4304
pISSN - 0896-8608
DOI - 10.1177/0896860819893817
Subject(s) - peritoneal dialysis , kt/v , medicine , dialysis , body water , dialysis adequacy , population , anthropometry , standard error , statistics , surgery , mathematics , body weight , environmental health
Background: Current guidelines for the prescription of peritoneal dialysis dose rely on a single cut-off ‘minimal’ value of K t / V . To apply this in the clinic, this requires an accurate estimation of V , the volume of urea distribution that equates to the total body water (TBW). This analysis sought to determine the accuracy to which V can be estimated.Methods: A literature search was undertaken of studies comparing TBW estimation using two or three of the following methods: isotopic dilution (gold standard), anthropometric equations (e.g. Watson formula) and bioimpedance analysis. Studies of healthy and dialysis populations of all ages were included. Mean differences and 95% limits of agreement (LOA) were extracted and pooled.Results: In 44 studies (31 including dialysis subjects), the between-method population means were typically within 1–1.5 L of each other, although larger bias was seen when applying anthropometric equations to different racial groups. However, the 95% LOA for all comparisons were consistently wide, typically ranging ±12–18% of the TBW. For a typical individual whose TBW is 35 L with a measured K t / V of 1.7, this translates into a range of K t / V 1.4–2.05.Conclusions: There are limitations to the accuracy of estimation of V which call into question the validity of applying a single threshold K t / V value as indicative of adequate dialysis. This should be taken into account in guideline development such that if a target K t / V was deemed appropriate that this should be expressed as a range; alternatively single targets should be avoided and dialysis dose should be determined according to patient need.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom