Haemodynamic and Bispectral Index Response to Insertion of the Streamlined Liner of the Pharynx Airway (SLIPA™): Comparison with the Laryngeal Mask Airway
Author(s) -
G. D. Puri,
Harihar V. Hegde,
Aveek Jayant,
Ishwar Bhukal
Publication year - 2008
Publication title -
anaesthesia and intensive care
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.494
H-Index - 62
eISSN - 1448-0271
pISSN - 0310-057X
DOI - 10.1177/0310057x0803600312
Subject(s) - medicine , bispectral index , anesthesia , hemodynamics , propofol , airway , laryngeal mask airway , pharynx , mean arterial pressure , heart rate , blood pressure , laryngeal masks , vascular resistance , cardiac index , surgery , cardiac output
The newly developed supralaryngeal airway Streamlined Liner of the Pharynx Airway (SLIPA) has been compared successfully to the LMA, but the haemodynamic response to its insertion has not been evaluated in a randomised study. We compared haemodynamic and Bispectral index (BIS) responses to insertion of the SLIPA with classic LMA after standardising the anaesthetic technique using BIS to monitor and control the anaesthetic depth. One hundred patients were randomised to receive either a classic LMA or SLIPA following induction with fentanyl and propofol titrated to a target BIS of 40 and compared heart rate, mean arterial pressure and BIS responses to insertion. There was a significant rise in mean arterial pressure from the pre-stimulus value (73.8 [10.6] mmHg, mean +/- SD) at two and three minutes (P<0.05) following insertion of the LMA with maximum rise (80.8 [11.5] mmHg) seen at two minutes. There was a significant rise in mean arterial pressure from the pre-stimulus value (73.2 [12.6] mmHg) at one, two, three, four and five minutes (P<0.05) following insertion of the SLIPA with maximum rise (86.9 [15.1] mmHg) observed at three minutes. Mean arterial pressure was significantly higher (P<0.05) with SLIPA at two, three, four and five minutes. BIS increased significantly (P<0.05) at one, two, three, four and five minutes following insertion of both the devices, but there was no significant difference between the groups. There was a significantly higher (P=0.001) incidence of blood on the device with the SLIPA (20/50 vs. 6/50 with LMA). Thus, insertion of SLIPA causes significantly higher blood-pressure response but similar BIS response compared to the LMA.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom