z-logo
open-access-imgOpen Access
Adverse Physiological Events under Anaesthesia and Sedation: A Pilot Audit of Electronic Patient Records
Author(s) -
C. M. Grant,
Guy L. Ludbrook,
E. A. Hampson,
R. A. Semenov,
Randy Willis
Publication year - 2008
Publication title -
anaesthesia and intensive care
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.494
H-Index - 62
eISSN - 1448-0271
pISSN - 0310-057X
DOI - 10.1177/0310057x0803600213
Subject(s) - medicine , adverse effect , sedation , anesthesia , perioperative , audit , patient safety , laryngospasm , quality management , emergency medicine , medical emergency , intensive care medicine , health care , management system , airway , management , economics , economic growth
Review of perioperative activity including adverse events, throughput and compliance with 'best practice', can theoretically be used to optimise healthcare delivery. Computer-based analysis of electronic patient records could provide a practical means to manage quality improvement. This pilot study examined the effectiveness of such a system in practice. All intraoperative patient notes and physiological data were collected over 17 months in a rural hospital using data from an electronic record-keeping system. Algorithms were developed to automatically identify potential adverse events based on physiological measures. Each computer-identified event was reviewed by a panel of three anaesthetists and assessed for validity, severity and probable cause. Two areas were identified to pilot quality improvement activities-sedation for colonoscopies and inhalational anaesthesia with desflurane. Specific 'in-house' guidelines were created for these procedures and feedback on the patterns of adverse events were provided to anaesthetic staff A total of 138 separate adverse events were identified for all operative cases over 17 months, with an overall adverse event incidence of 3.3%. The adverse event incidence during colonoscopy and laryngospasm/hypoxia during desflurane anaesthesia was 6.3% and 1.3% respectively. This decreased to 2.8% (P <0.005) and 0.13% (P <0.0001) respectively for the nine months following feedback and the introduction of guidelines. Anaesthesia information systems can be an effective quality improvement tool and may enhance existing tools such as incident reporting systems.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom