z-logo
open-access-imgOpen Access
Derivo Embolization Device for the Treatment of Intracranial Aneurysms
Author(s) -
Felipe Padovani Trivelato,
Daniel Giansante Abud,
Alexandre Cordeiro Ulhôa,
Eduardo Waihrich,
Thiago Giansante Abud,
Luis Henrique Castro Afonso,
Guilherme Seizem Nakiri,
Guilherme Duarte de Castro,
Bruno de Sousa Mendes Parente,
Rodrigo dos Santos Silva,
Luciano Bambini Manzato,
Lucas Eduardo Bonadio,
Dinark Conceição Viana,
José Ricardo Vanzin,
Carlos Eduardo Baccin,
Marco Túlio Salles Rezende
Publication year - 2019
Publication title -
stroke
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.397
H-Index - 319
eISSN - 1524-4628
pISSN - 0039-2499
DOI - 10.1161/strokeaha.119.025407
Subject(s) - medicine , embolization , aneurysm , odds ratio , occlusion , surgery , radiology , clinical endpoint , prospective cohort study , confidence interval , randomized controlled trial
Background and Purpose- Flow diverter technology improvements are necessary to provide safe and good results and enable the treatment of a larger variety of aneurysms. We report a nationwide experience with the Derivo Embolization Device in the treatment of intracranial aneurysms. Methods- BRAIDED (Brazilian Registry of Aneurysms Assigned to Intervention With the Derivo Embolization Device) is a multicenter, prospective, interventional, single-arm trial of the Derivo Embolization Device for the treatment of intracranial aneurysms. The primary effectiveness end point was total aneurysm occlusion at 6- and 12-month angiographies. The secondary safety end point was the absence of serious adverse events during follow-up. Univariable and multivariable logistic regression was performed to identify predictors of aneurysm persistence, periprocedural complications, and adverse events during follow-up. Results- Between December 2016 and October 2018, 146 patients harboring 183 intracranial aneurysms were treated in 151 interventions at 7 centers. Derivo Embolization Device placement was technically successful in all patients. Most aneurysms (86.9%) were located at the internal carotid artery, and the mean diameter was 6.7 mm. At 6 months, 113 of 140 (80.7%) aneurysms met the study's primary end point, and 74 of 83 (89.2%) met the study's primary end point at 12 months. Saccular morphology of the aneurysm (odds ratio, 5.66; 95% CI, 1.01-31.77) and the presence of a branch arising from the sac (odds ratio, 6.36; 95% CI, 2.11-22.36) predicted persistence. A long duration of follow-up (odds ratio, 0.86; 95% CI, 0.78-0.95) predicted total occlusion. Of the 146 enrolled patients, 138 (94.5%) were treated without serious adverse events during follow-up. In the multivariable analysis, aneurysms located at a sidewall were less likely to experience these events than those located at bifurcations (odds ratio, 0.07; 95% CI, 0.01-0.51). Conclusions- The Derivo Embolization Device is a safe and effective treatment for intracranial aneurysms. Clinical Trial Registration- URL: http://plataformabrasil.saude.gov.br/login.jsf. Unique identifier: CAAE 77089717.7.1001.5125.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom