Changes in Wall Shear Stress of Cerebral Arteriovenous Malformation Feeder Arteries After Embolization and Surgery
Author(s) -
Ali Alaraj,
Sophia F. Shakur,
Sepideh AminHanjani,
Hassan Mostafa,
Sajeel Khan,
Victor Aletich,
Fady T. Charbel
Publication year - 2015
Publication title -
stroke
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.397
H-Index - 319
eISSN - 1524-4628
pISSN - 0039-2499
DOI - 10.1161/strokeaha.115.008836
Subject(s) - medicine , embolization , arteriovenous malformation , shear stress , cerebral arteries , surgery , radiology , anatomy , materials science , composite material
Background and Purpose— Wall shear stress (WSS) has been implicated as an important stimulus for vascular remodeling. The purpose of this study is to measure WSS in AVM arterial feeders using quantitative magnetic resonance angiography pre- and post-embolization/surgery. Methods— Records of patients who underwent AVM embolization and surgical resection at our institution between 2007 and 2013 and had WSS, flow rate, and vessel diameter obtained pre- and post-treatment using quantitative magnetic resonance angiography were retrospectively reviewed. WSS was compared between the feeder and contralateral artery pre- and post-embolization/surgery. Results— Twenty-one patients were included (mean age 34 years, 19% hemorrhagic presentation), with Spetzler–Martin grades 1 to 4. WSS, blood flow, and vessel diameter were assessed in a total of 51 feeder arteries. At baseline, mean WSS was significantly higher compared with the contralateral vessel (29.7±12.0 dynes/cm2 versus 23.3±11.0 dynes/cm2 ;P =0.007). After embolization (23.0 dynes/cm2 versus 22.5 dynes/cm2 ;P =0.78) and surgery (17.9 dynes/cm2 versus 23.2 dynes/cm2 ;P =0.09), WSS was not significantly different than in the contralateral vessel. Reduced WSS post-embolization corresponded to significantly decreased flow (338.1 mL/min versus 170.3 mL/min;P <0.001) and smaller vessel diameter (3.7 mm versus 3.5 mm;P =0.01).Conclusions— Enlargement of cerebral AVM arterial feeders is insufficient to compensate for increased blood flow, creating high WSS. After treatment, flow diminishes and so WSS and vessel diameter concomitantly decrease. Thus, WSS plays a pivotal role in vascular remodeling that may be exploited to monitor AVM response to treatment or understand other high-flow vascular pathologies.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom