Predictors of Permanent Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement ‐ A Systematic Review and Meta‐Analysis
Author(s) -
Waqas Ullah,
Salman Zahid,
Syeda Ramsha Zaidi,
Deepika Sarvepalli,
Shujaul Haq,
Sohaib Roomi,
Maryam Mukhtar,
Muhammad Atif Khan,
Smitha Narayana Gowda,
Nicholas Ruggiero,
Alec Vishnevsky,
David L. Fischman
Publication year - 2021
Publication title -
journal of the american heart association
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.494
H-Index - 85
ISSN - 2047-9980
DOI - 10.1161/jaha.121.020906
Subject(s) - medicine , cardiology , permanent pacemaker , meta analysis , valve replacement , aortic valve replacement , surgery , stenosis
Background As transcatheter aortic valve replacement (TAVR) technology expands to healthy and lower‐risk populations, the burden and predictors of procedure‐related complications including the need for permanent pacemaker (PPM) implantation needs to be identified. Methods and Results Digital databases were systematically searched to identify studies reporting the incidence of PPM implantation after TAVR. A random‐ and fixed‐effects model was used to calculate unadjusted odds ratios (OR) for all predictors. A total of 78 studies, recruiting 31 261 patients were included in the final analysis. Overall, 6212 patients required a PPM, with a mean of 18.9% PPM per study and net rate ranging from 0.16% to 51%. The pooled estimates on a random‐effects model indicated significantly higher odds of post‐TAVR PPM implantation for men (OR, 1.16; 95% CI, 1.04–1.28); for patients with baseline mobitz type‐1 second‐degree atrioventricular block (OR, 3.13; 95% CI, 1.64–5.93), left anterior hemiblock (OR, 1.43; 95% CI, 1.09–1.86), bifascicular block (OR, 2.59; 95% CI, 1.52–4.42), right bundle‐branch block (OR, 2.48; 95% CI, 2.17–2.83), and for periprocedural atriorventricular block (OR, 4.17; 95% CI, 2.69–6.46). The mechanically expandable valves had 1.44 (95% CI, 1.18–1.76), while self‐expandable valves had 1.93 (95% CI, 1.42–2.63) fold higher odds of PPM requirement compared with self‐expandable and balloon‐expandable valves, respectively. Conclusions Male sex, baseline atrioventricular conduction delays, intraprocedural atrioventricular block, and use of mechanically expandable and self‐expanding prosthesis served as positive predictors of PPM implantation in patients undergoing TAVR.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom