z-logo
open-access-imgOpen Access
Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
Author(s) -
Pierre Deharo,
Arnaud Bisson,
Julien Herbert,
Thibaud Lacour,
Christophe Saint Etienne,
Leslie GrammaticoGuillon,
Alizée Porto,
Frédéric Collart,
Thierry Bourguig,
Thomas Cuisset,
Laurent Fauchier
Publication year - 2019
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.119.043971
Subject(s) - medicine , interquartile range , stenosis , relative risk , cardiology , valve replacement , propensity score matching , balloon , cohort , surgery , aortic valve stenosis , aortic valve , confidence interval
Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. Methods: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. Results: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10–599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; correctedP =0.005), cardiovascular death (relative risk, 0.82; correctedP =0.002), and rehospitalization for heart failure (relative risk, 0.84; correctedP <0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; correctedP <0.0001).Conclusions: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom