z-logo
open-access-imgOpen Access
Association Between Use of Primary-Prevention Implantable Cardioverter-Defibrillators and Mortality in Patients With Heart Failure
Author(s) -
Benedikt Schrage,
Alicia Uijl,
Lina Benson,
Dirk Westermann,
Marcus Ståhlberg,
Davide Stolfo,
Ulf Dahlström,
Cecilia Linde,
Frieder Braunschweig,
Gianluigi Savarese
Publication year - 2019
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.119.043012
Subject(s) - medicine , heart failure , hazard ratio , ejection fraction , implantable cardioverter defibrillator , cardiology , cardiac resynchronization therapy , proportional hazards model , sudden cardiac death , cohort , population , propensity score matching , confidence interval , environmental health
Background: Most randomized trials on implantable cardioverter-defibrillator (ICD) use for primary prevention of sudden cardiac death in heart failure with reduced ejection fraction enrolled patients >20 years ago. We investigated the association between ICD use and all-cause mortality in a contemporary heart failure with reduced ejection fraction cohort and examined relevant subgroups. Methods: Patients from the Swedish Heart Failure Registry fulfilling the European Society of Cardiology criteria for primary-prevention ICD were included. The association between ICD use and 1-year and 5-year all-cause and cardiovascular (CV) mortality was assessed by Cox regression models in a 1:1 propensity score–matched cohort and in prespecified subgroups. Results: Of 16 702 eligible patients, only 1599 (10%) had an ICD. After matching, 1305 ICD recipients were compared with 1305 nonrecipients. ICD use was associated with a reduction in all-cause mortality risk within 1 year (hazard ratio, 0.73 [95% CI, 0.60–0.90]) and 5 years (hazard ratio, 0.88 [95% CI, 0.78–0.99]). Results were consistent in all subgroups including patients with versus without ischemic heart disease, men versus women, those aged <75 versus ≥75 years, those with earlier versus later enrollment in the Swedish heart failure registry, and patients with versus without cardiac resynchronization therapy. Conclusions: In a contemporary heart failure with reduced ejection fraction population, ICD for primary prevention was underused, although it was associated with reduced short- and long-term all-cause mortality. This association was consistent across all the investigated subgroups. These results call for better implementation of ICD therapy.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom