z-logo
open-access-imgOpen Access
Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy
Author(s) -
Daniel J. Friedman,
Haikun Bao,
Erica S. Spatz,
Jeptha P. Curtis,
James P. Daubert,
Sana M. AlKhatib
Publication year - 2016
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.116.022913
Subject(s) - medicine , hazard ratio , cardiac resynchronization therapy , cardiology , heart failure , confidence interval , ejection fraction , coronary artery disease , implantable cardioverter defibrillator , qrs complex
Background: A prolonged PR interval is common among cardiac resynchronization therapy (CRT) candidates; however, the association between PR interval and outcomes is unclear, and the data are conflicting. Methods: We conducted inverse probability weighted analyses of 26 451 CRT-eligible (ejection fraction ≤35, QRS ≥120 ms) patients from the National Cardiovascular Data Registry ICD Registry to assess the association between a prolonged PR interval (≥230 ms), receipt of CRT with defibrillator (CRT-D) versus implantable cardioverter defibrillator (ICD), and outcomes. We first tested the association between a prolonged PR interval and outcomes among patients stratified by device type. Next, we performed a comparative effectiveness analysis of CRT-D versus ICD among patients when stratified by PR interval. Using Medicare claims data, we followed up with patients up to 5 years for incident heart failure hospitalization or death. Results: Patients with a PR≥230 ms (15%; n=4035) were older and had more comorbidities, including coronary artery disease, atrial arrhythmias, diabetes mellitus, and chronic kidney disease. After risk adjustment, a PR≥230 ms (versus PR<230 ms) was associated with increased risk of heart failure hospitalization or death among CRT-D (hazard ratio, 1.23; 95% confidence interval, 1.14–1.31;P <0.001) but not ICD recipients (hazard ratio, 1.08; 95% confidence interval, 0.97–1.20;P =0.17) (P interaction =0.043). CRT-D (versus ICD) was associated with lower rates of heart failure hospitalization or death among patients with PR<230 ms (hazard ratio, 0.79; 95% confidence interval, 0.73–0.85;P <0.001) but not PR≥230 ms (hazard ratio, 1.01; 95% confidence interval, 0.87–1.17;P =0.90) (P interaction =0.0025).Conclusions: A PR≥230 ms is associated with increased rates of heart failure hospitalization or death among CRT-D patients. The real-world comparative effectiveness of CRT-D (versus ICD) is significantly less among patients with a PR≥230 ms in comparison with patients with a PR<230 ms.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom