Assessment of the Human Coronary Collateral Circulation
Author(s) -
Tobias Traupe,
Steffen Gloekler,
Stefano F. de Marchi,
Gerald S. Werner,
Christian Seiler
Publication year - 2010
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.109.930651
Subject(s) - medicine , intensive care , university hospital , cardiology , intensive care medicine
Cardiovascular disease is the leading cause of death in industrialized countries and may become the most important reason for mortality worldwide.1 In patients suffering from coronary artery disease (CAD), the size of myocardial infarction mainly determines outcome.2 Accordingly, the primary strategy to reduce cardiovascular mortality is by shrinking infarct size (IS) (Figure 1A).3 In the clinical setting of acute myocardial infarction, Antoniucci et al4,5 documented in 1164 patients undergoing primary percutaneous coronary intervention (PCI) that the presence of angiographic collaterals before PCI purported a survival benefit compared with the situation without them (Figure 2). As a surrogate for IS, studies on the effect of myocardial salvage procedures have employed the magnitude of ECG ST-segment elevation during coronary balloon occlusion (Figure 3).6,7 IS, measured as the degree of ECG ST-segment elevation during a 1-minute coronary occlusion, is influenced by the following factors: duration of occlusion, ischemic area at risk for myocardial infarction (AR), collateral blood supply to the ischemic zone, ischemic preconditioning, and myocardial oxygen consumption.8 In the context of a single brief artificial coronary occlusion of uniform duration without preceding bouts of ischemia (Figure 3),6 ECG signs of ischemia are influenced predominantly by the AR and by collateral supply to this region. Furthermore, Figure 1B3 illustrates that AR and collateral supply are inversely related to each other (ie, AR tends to shrink toward zero in the presence of well-functioning collaterals). They are termed sufficient if they prevent an ECG ST-segment elevation of ≥0.1 mV during a 1-minute coronary balloon occlusion; otherwise, they are termed insufficient collaterals.Figure 1. Schematic drawing of the coronary artery circulation without (A) and with interarterial anastomoses (B) between the right coronary artery and the occluded left anterior descending artery (occluded downstream …
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom