z-logo
open-access-imgOpen Access
Response to Letter Regarding Article, “Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study”
Author(s) -
Eberhard Grube,
Lutz Buellesfeld,
Ulrich Gerckens,
Ralf Mueller,
Maurizio Menichelli,
Thomas Schmidt,
Jean Claude Laborde,
Thomas Felderhoff,
Stein Iversen,
Barthel Sauren,
B. Zickmann,
Gregg W. Stone
Publication year - 2007
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.107.688671
Subject(s) - medicine , percutaneous , prosthesis , disease , cardiology , aortic valve , surgery
BACKGROUNDThe morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve).METHODS AND RESULTSSymptomatic high-risk patients with an aortic valve area <1 cm2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2+/-10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4+/-3.0 mm Hg; P<0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital.CONCLUSIONSPercutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom