z-logo
open-access-imgOpen Access
Pulmonary Embolism and Fever
Author(s) -
Gaetano Nucifora,
Luigi P. Badano,
Fjoralba Hysko,
Giuseppe Allocca,
Pasquale Gianfagna,
P. Fioretti
Publication year - 2007
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/circulationaha.106.674358
Subject(s) - radiological weapon , medicine , surgery
Case presentation: A 39-year-old woman with chronic alcoholism became febrile (38.8°C) and markedly dyspneic on the fourth postoperative day of gastric surgery. Laboratory evaluation revealed anemia (hemoglobin 8.5 g/dL), thrombocytopenia (platelet count 30 000/mm3), and elevation of inflammatory markers (white blood cell count 18 000/mm3, C-reactive protein 187 mg/dL, and erythrocyte sedimentation rate 50 mm/s). Limb venous ultrasonography was negative for deep vein thrombosis, but pulmonary embolism (PE) was diagnosed on the basis of contrast-enhanced multidetector-row spiral computed tomography (MSCT; Figure 1A). Anticoagulation therapy was considered to be contraindicated because of recent surgery and thrombocytopenia, and a retrievable inferior vena cava filter was placed. With persistent high-grade fever and dyspnea and with the finding of Streptococcus agalactiae bacteremia, the patient underwent a transthoracic echocardiography examination on the sixth postoperative day that showed a large, mobile vegetation attached to the pulmonary valve (Figure 1B). A diagnosis of infective endocarditis (IE) of the pulmonary valve complicated by septic PE was then made, and the patient was referred for vena cava filter removal and pulmonary valve replacement. During vena cava filter removal, an acute thromboembolic stroke occurred, and transesophageal echocardiography documented a patent foramen ovale with right-to-left shunt. Ten days later, the patient underwent successful pulmonary valve replacement and surgical closure of the patent foramen ovale. Figure 1. A, MSCT shows a large filling defect in the main pulmonary artery, above the pulmonary valve (black arrow), and a filling defect in the terminal part of the right pulmonary artery (white arrow). B, 2D transthoracic echocardiography performed a few days later shows a large vegetation attached to the arterial surface of the medial cusp of the pulmonary valve. Ao indicates ascending aorta; LA, left atrium; PA, pulmonary artery; and Veg, vegetation.Fever has long been recognized as commonly accompanying …

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom