Development of Light-Responsive Liquid Crystalline Elastomers to Assist Cardiac Contraction
Author(s) -
Cecilia Ferrantini,
José Manuel Pioner,
Daniele Martella,
Raffaele Coppini,
Nicoletta Piroddi,
Paolo Paoli,
Martino Calamai,
Francesco S. Pavone,
Diederik S. Wiersma,
Chiara Tesi,
Elisabetta Cerbai,
Corrado Poggesi,
Leonardo Sacconi,
Camilla Parmeggiani
Publication year - 2019
Publication title -
circulation research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.899
H-Index - 336
eISSN - 1524-4571
pISSN - 0009-7330
DOI - 10.1161/circresaha.118.313889
Subject(s) - biocompatible material , biomedical engineering , contraction (grammar) , materials science , cardiac muscle , stimulus (psychology) , light intensity , elastomer , nanotechnology , medicine , composite material , psychology , physics , optics , psychotherapist
Rationale: Despite major advances in cardiovascular medicine, heart disease remains a leading cause of death worldwide. However, the field of tissue engineering has been growing exponentially in the last decade and restoring heart functionality is now an affordable target; yet, new materials are still needed for effectively provide rapid and long-lasting interventions. Liquid crystalline elastomers (LCEs) are biocompatible polymers able to reversibly change shape in response to a given stimulus and generate movement. Once stimulated, LCEs can produce tension or movement like a muscle. However, so far their application in biology was limited by slow response times and a modest possibility to modulate tension levels during activation. Objective: To develop suitable LCE-based materials to assist cardiac contraction. Methods and Results: Thanks to a quick, simple, and versatile synthetic approach, a palette of biocompatible acrylate-based light-responsive LCEs with different molecular composition was prepared and mechanically characterized. Out of this, the more compliant one was selected. This material was able to contract for some weeks when activated with very low light intensity within a physiological environment. Its contraction was modulated in terms of light intensity, stimulation frequency, and ton /toff ratio to fit different contraction amplitude/time courses, including those of the human heart. Finally, LCE strips were mounted in parallel with cardiac trabeculae, and we demonstrated their ability to improve muscular systolic function, with no impact on diastolic properties.Conclusions: Our results indicated LCEs are promising in assisting cardiac mechanical function and developing a new generation of contraction assist devices.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom