Comparative Safety of Bioabsorbable Polymer Everolimus-Eluting, Durable Polymer Everolimus-Eluting, and Durable Polymer Zotarolimus-Eluting Stents in Contemporary Clinical Practice
Author(s) -
Nadia R. Sutton,
Milan Seth,
Ryan D. Madder,
Devraj Sukul,
Simon Dixon,
Louis Can,
Hitinder S. Gurm
Publication year - 2021
Publication title -
circulation cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.621
H-Index - 95
eISSN - 1941-7632
pISSN - 1941-7640
DOI - 10.1161/circinterventions.120.009850
Subject(s) - zotarolimus , everolimus , polymer , materials science , medicine , drug eluting stent , surgery , stent , composite material , restenosis
Background: Uncertainty exists over whether stents commonly used for percutaneous coronary intervention have comparable short- and long-term safety. The objective of this study was to determine the outcomes of patients treated with bioabsorbable polymer everolimus-eluting (BP-EES; Synergy, Boston Scientific), durable polymer everolimus-eluting (DP-EES; XIENCE, Abbott Vascular), or durable polymer zotarolimus-eluting (DP-ZES; Resolute, Medtronic) stents in routine clinical practice. Methods: All percutaneous coronary intervention cases from 48 hospitals performed after the introduction of the BP-EES stent in 2015 until the first quarter of 2018 were included. Propensity-matched multivariable analysis was used to adjust for differences in baseline characteristics and procedural variables. After matching, we performed pair-wise comparisons between DP-EES and BP-EES, DP-EES and DP-ZES, and BP-EES and DP-ZES for in-hospital postpercutaneous coronary intervention outcomes. We also evaluated 2-year postdischarge mortality in a subset of patients who could be matched to Medicare data. Results: During the study period, 53 724 percutaneous coronary intervention cases were performed. A total of 59% of patients were treated with DP-EES stents, 14% with BP-EES stents, and 27% with DP-ZES stents. Although baseline characteristics of patients differed between stent types, these differences were attenuated after matching. In the matched cohort, there was no difference in in-hospital mortality, stent thrombosis, or postprocedural stroke (a falsification end point) between BP-EES, DP-EES, and DP-ZES. After matching, there was no difference in 2-year postdischarge mortality (DP-EES versus BP-EES hazard ratio 0.91,P =0.50; DP-EES versus DP-ZES hazard ratio 1.03,P =0.77; BP-EES versus DP-ZES hazard ratio 1.20,P =0.29).Conclusions: Our data suggest similar risk-adjusted in-hospital outcomes among drug-eluting stent platforms commonly used in clinical practice. The absence of a difference in 2-year mortality between BP-EES, DP-EES, and DP-ZES suggests that stent choice decisions could be made based on other factors, including durability, availability, and cost.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom