Healthy Strut Coverage After Coronary Stent Implantation
Author(s) -
Hiroyuki Jinnouchi,
Fumiyuki Otsuka,
Yu Sato,
Rahul Bhoite,
Atsushi Sakamoto,
Sho Torii,
Kazuyuki Yahagi,
Anne Cornelissen,
Masayuki Mori,
Rika Kawakami,
Frank D. Kolodgie,
Renu Virmani,
Aloke V. Finn
Publication year - 2020
Publication title -
circulation cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.621
H-Index - 95
eISSN - 1941-7632
pISSN - 1941-7640
DOI - 10.1161/circinterventions.119.008869
Subject(s) - medicine , cutoff , optical coherence tomography , histology , stent , radiology , nuclear medicine , gold standard (test) , predictive value , neointima , autopsy , pathology , restenosis , physics , quantum mechanics
Background: Struts have been considered as covered when tissue overlying the struts is >0 μm by optical coherence tomography (OCT). However, there is no confirmatory study to validate this definition by histology which is the gold standard. The aim of the present study was to assess the appropriate cutoff value of neointimal thickness of stent strut coverage by OCT with histology confirmation. Methods: We performed ex vivo OCT imaging of human coronary arteries with stents at autopsy. A total of 46 stents in 39 vessels from 25 patients were examined in this study, and a total of 165 cross-sectional images were co-registered with histology to determine the optimal cutoff value for strut coverage by OCT which was defined as luminal endothelial cells with 2 abluminal layers of smooth muscles cells and matrix. Considering the resolution of OCT is 10 to 20 μm, the cutoff values were assessed at ≥20, ≥40, and ≥60 μm. Results: A total of 2235 struts were reviewed by histology, 1216 were considered as well-matched struts which were analyzed in this study. By histology, 160 struts were identified as uncovered, while 1056 struts were covered. The OCT assessment without consideration of neointimal thickness yielded a poor specificity of 37.5% and sensitivity 100%. Of 3 cutoff values, the cutoff value of ≥40 μm yielded the best sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%) as compared with ≥20 and ≥60 μm. Conclusions: Neointimal thickness ≥40 μm by OCT yielded the most accurate cutoff value to identify stent strut coverage validated by histology.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom