Assessment of Long-Term Structural Deterioration of Transcatheter Aortic Bioprosthetic Valves Using the New European Definition
Author(s) -
Éric Durand,
Anastasia Sokoloff,
Marina Ureña,
Bernard Chevalier,
Stéphan Chassaing,
Romain Didier,
Christophe Tron,
PierreYves Litzler,
Claire Bouleti,
Dominique Himbert,
Thomas Hovasse,
Olivier Bar,
G. Avinée,
Bernard Iung,
Didier Blanchard,
Martine Gilard,
Alain Cribier,
Thierry Lefévre,
Hélène Eltchaninoff
Publication year - 2019
Publication title -
circulation cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.621
H-Index - 95
eISSN - 1941-7632
pISSN - 1941-7640
DOI - 10.1161/circinterventions.118.007597
Subject(s) - medicine , cumulative incidence , cardiology , incidence (geometry) , aortic valve , percutaneous , surgery , cohort , physics , optics
Background: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. Methods and Results: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%–85.5%) and 18.6% (95% CI, 15.3%–21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%–2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%–8.4%) and 4.2% (95% CI, 2.9%–5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%–1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. Conclusions: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.