Subject(s) - medicine , target lesion , life expectancy , thrombosis , percutaneous coronary intervention , population , everolimus , surgery , myocardial infarction , environmental health
Background— Relative benefits of bioresorbable vascular scaffolds (BVS) compared with everolimus-eluting stents (EES) are expected to accrue after complete bioresorption. Methods and Results— We built a decision analytic Markov model comparing BVS and EES for a contemporary percutaneous coronary intervention population. Procedure-related morbidity and outcome data from the available literature were used to derive model probabilities. The net benefit of BVS and EES was estimated in terms of quality-adjusted life expectancy. Under the assumption of no risk for device thrombosis and target lesion revascularization with BVS beyond 3 years, the equipoise in quality-adjusted life expectancy (12.86) between BVS and EES was achieved 19 years after implantation. The maximum tolerable excess risk of 3-year BVS thrombosis equalizing the model-predicted quality-adjusted life expectancy of BVS and EES at 10 years was 1.40, corresponding to an absolute tolerable rate of 1.45%. Conclusions— At the currently observed relative increase in device thrombosis and under the extreme hypothesis of no scaffold thrombosis and target lesion revascularization beyond 3 years, the incremental benefit of BVS over EES becomes apparent only after 19 years. This simulation suggests that there is a small degree of benefit that clinicians and decision-makers may expect from the first-generation BVS at the current risk of device thrombosis. Manufacturers should target scaffold thrombosis rates <1.45% at 3 years to make their technologies attractive during a 10-year horizon.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom