z-logo
open-access-imgOpen Access
Noninvasive assessment of cerebral collateral blood supply through the ophthalmic artery.
Author(s) -
Peter A. Schneider,
M E Rossman,
Eugene F. Bernstein,
E B Ringelstein,
Shirley M. Otis
Publication year - 1991
Publication title -
stroke
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.397
H-Index - 319
eISSN - 1524-4628
pISSN - 0039-2499
DOI - 10.1161/01.str.22.1.31
Subject(s) - medicine , ophthalmic artery , middle cerebral artery , internal carotid artery , collateral circulation , blood flow , occlusion , common carotid artery , cerebral arteries , artery , cardiology , radiology , ischemia , carotid arteries
We assessed the potential of 2-MHz pulsed-wave transorbital Doppler ultrasonography to delineate the role of the ophthalmic artery as a source of collateral cerebral blood supply by comparing oculopneumoplethysmography, transorbital Doppler ultrasonography, periorbital continuous-wave Doppler ultrasonography, and transcranial Doppler ultrasonography in 25 patients with unilateral internal carotid artery occlusion and five controls with 10 normal internal carotid arteries. Systolic ophthalmic artery blood velocity was reduced ipsilateral to an internal carotid artery occlusion (38.2 +/- 10.2 cm/sec) compared with the contralateral and control velocities (46.0 +/- 10.3 and 47.5 +/- 6.8 cm/sec, respectively; p less than 0.05). Ophthalmic systolic pressure measured by oculopneumoplethysmography was 94.7 +/- 13.2 mm Hg ipsilateral to an internal carotid artery occlusion compared with 108.4 +/- 15.3 mm Hg on the contralateral side (p less than 0.01). Transorbital and periorbital Doppler ultrasonography detected reversed ophthalmic artery blood flow ipsilateral to an internal carotid artery occlusion in 44.0% and 40.0% of the patients, respectively. Systolic middle cerebral artery blood velocity was 55.2 +/- 22.3 cm/sec ipsilateral to an internal carotid artery occlusion compared with 79.4 +/- 23.5 cm/sec on the contralateral side (p less than 0.05) and 101.2 +/- 18.9 cm/sec in the controls (p less than 0.05). Reversed ophthalmic artery blood flow was associated with a low middle cerebral artery blood velocity and lack of major intracerebral collaterals. Transorbital Doppler ultrasonography permits noninvasive evaluation of the ophthalmic artery.(ABSTRACT TRUNCATED AT 250 WORDS)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom