Comparison of local cerebral blood flow determined by thermal and hydrogen clearance.
Author(s) -
Casey Gaines,
L P Carter,
Robert M. Crowell
Publication year - 1983
Publication title -
stroke
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.397
H-Index - 319
eISSN - 1524-4628
pISSN - 0039-2499
DOI - 10.1161/01.str.14.1.66
Subject(s) - medicine , cerebral blood flow , blood flow , hydrogen , cats , diffusion , biomedical engineering , anesthesia , cardiology , thermodynamics , chemistry , physics , organic chemistry
Local cerebral blood flow (1CBF) was measured simultaneously in ten cats with (1) a large surface thermal diffusion probe resting on the cortex and (2) hydrogen clearance curves from implanted electrodes surrounding the thermal probe. A close correlation was found between 1CBF values obtained by the two methods. Since hydrogen clearance is accepted as quantitative, the data suggest that the thermal diffusion technique is a reliably quantitative means of measuring local cerebral blood flow.