Monitoring 24-hour blood pressure in a drug trial. Evaluation of a noninvasive device.
Author(s) -
G Berglund,
Ulf dé Fairé,
Jan Castenfors,
G Andersson,
Marianne Hartford,
Hans Liedholm,
Susanne Ljungman,
Thomas Thulin,
John Wikstrand
Publication year - 1985
Publication title -
hypertension
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.986
H-Index - 265
eISSN - 1524-4563
pISSN - 0194-911X
DOI - 10.1161/01.hyp.7.5.688
Subject(s) - medicine , blood pressure , heart rate , placebo , ambulatory blood pressure , anesthesia , ambulatory , cardiology , surgery , pathology , alternative medicine
To test the usefulness of noninvasive ambulatory 24-hour blood pressure recording, the Del Mar Avionics system was used in a double-blind clinical trial in which 31 hypertensive patients were randomly allocated to receive placebo or pafenolol (25 mg or 50 mg), a novel, long-acting, highly selective beta-blocker, once daily. The results of 24-hour blood pressure and heart rate recording after 4 weeks of treatment were compared with a previous 24-hour recording performed after a 4-week placebo run-in period using the 3-hour mean of recordings performed every 7.5 minutes both day and night. Furthermore, 24-hour means were analyzed in each patient before and after 4 weeks. The system was easy to use and, judging from two placebo periods in the same patients, the reproducibility was good. The 24-hour blood pressure and heart rate recordings showed a clear dose-response relationship for pafenolol that could not be detected by ordinary casual readings. A daily dose of 25 mg of pafenolol significantly reduced blood pressure during the 9 hours after tablet intake (p less than 0.01), while 50 mg per day of pafenolol resulted in a significant reduction throughout the 24-hour period (p less than 0.01). The same pattern was seen for heart rate, which indicates a greater degree of beta-blockade during treatment with the higher dose. These results indicate that the tested noninvasive equipment is a useful tool for monitoring ambulatory 24-hour blood pressure. It gives important information impossible to obtain from single casual readings. This noninvasive method should be further evaluated to define its place in clinical work and as a research tool.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom