z-logo
open-access-imgOpen Access
Double-umbrella closure of atrial defects. Initial clinical applications.
Author(s) -
Jonathon Rome,
John F. Keane,
Stanton B. Perry,
Philip J. Spevak,
James E. Lock
Publication year - 1990
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.82.3.751
Subject(s) - medicine , shunt (medical) , embolization , surgery , catheter , intracardiac injection , ductus arteriosus , septum secundum , complication , patent foramen ovale , cardiology , percutaneous
Forty patients were catheterized for closure of atrial septal defects with the Rashkind patent ductus arteriosus umbrella device, a modified Rashkind umbrella device, and the newly designed Lock Clamshell Occluder. Patients weighed 8 kg or more (a requirement for transvenous access with the 11F delivery sheath) and had defects suitable for closure based on two-dimensional echocardiography. The new device was at least 1.6 times the diameter of the atrial septal defect as determined by balloon sizing at catheterization. Patients were followed up by telephone, clinical examination, and echocardiography at 6 months. We attempted closure in 34 patients, with atrial septal defects ranging in diameter from 3 to 22 mm; device sizes ranged from 17 to 33 mm. Initial device position immediately after release was correct in all patients. A cerebral embolus occurred in one elderly patient before device placement--the patient died 1 week later. Two instances of early device embolization occurred, and devices were retrieved by catheter without complication. Follow-up of 31 patients discharged with devices in place, for a total of 31 patient-years, has yielded no umbrella-related complications. Adequate imaging studies in 19 patients 6.5 months after device placement revealed no atrial shunt in 12; residual flow through separate, previously unrecognized atrial septal defects occurred in two; and small residual leaks (less than 3 mm) around devices were present in five patients. This initial success indicates that double-umbrella closure of atrial septal defects will aid in the treatment of intracardiac defects.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom