z-logo
open-access-imgOpen Access
Quantitative determination of aortic regurgitant volumes in dogs by ultrafast computed tomography.
Author(s) -
S J Reiter,
John A. Rumberger,
William L. Stanford,
Melvin L. Marcus
Publication year - 1987
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.76.3.728
Subject(s) - medicine , regurgitation (circulation) , stroke volume , aortic valve , cardiology , regurgitant fraction , stroke (engine) , diastole , ejection fraction , nuclear medicine , blood pressure , heart failure , mechanical engineering , engineering
Current imaging modalities can provide only a qualitative or semiquantitative measure of the severity of aortic regurgitation. Ultrafast computed tomography (CT) has the capability of rapid imaging (17 frames/sec) coupled with high spatial resolution (1.5 mm2). Eight millimeter thick images can be acquired to interrogate simultaneously the right and left ventricles. End-diastolic and end-systolic tomograms can be reconstructed serially from apex to base by Simpson's rule to provide end-diastolic and end-systolic volumes from which the right and left ventricular stroke volumes can be derived. To determine whether the difference between left and right ventricular stroke volume measured with ultrafast CT could be used to estimate the volume of experimentally induced aortic regurgitation, we studied six dogs in which proximal aortic electromagnetic flow probes had been implanted. Varying degrees of aortic regurgitation were induced by manipulation of a basket catheter through the aortic valve. During suspended respiration in the control state in the absence of aortic regurgitation, right and left ventricular stroke volumes measured with ultrafast CT were nearly identical (mean difference 1.0 +/- 1.2 ml [mean +/- SE]). In the presence of varying degrees of aortic regurgitation, regurgitant volume derived by ultrafast CT as the difference between right and left ventricular stroke volumes correlated closely to the regurgitant volume measured by the electromagnetic flow probe (r = .99, slope = .92, y intercept = 0.98 ml, SEE = 1.02 ml, n = 16). Regurgitant fraction also correlated closely to the regurgitant fraction measured by the electromagnetic flow probe (r = .94, slope = .98, y intercept = 0.66%, SEE = 4.73%, n = 16).(ABSTRACT TRUNCATED AT 250 WORDS)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom