z-logo
open-access-imgOpen Access
The potential gradient field created by epicardial defibrillation electrodes in dogs.
Author(s) -
P S Chen,
Patrick D. Wolf,
F.J. Claydon,
E G Dixon,
Humberto Vidaillet,
N.D. Danieley,
T.C. Pilkington,
R.E. Ideker
Publication year - 1986
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.74.3.626
Subject(s) - defibrillation , potential gradient , ventricular fibrillation , medicine , cardiology , defibrillation threshold , fibrillation , electrode , atrial fibrillation , physics , quantum mechanics
Knowledge of the potential gradient field created by defibrillation electrodes is important for the understanding and improvement of defibrillation. To obtain this knowledge by direct measurements, potentials were recorded from 60 epicardial, eight septal, and 36 right ventricular transmural electrodes in six open-chest dogs while 1 to 2 V shocks were given through defibrillation electrodes on the right atrium and left ventricular apex (RA. V) and on the right and left ventricles (RV .LV). The potential gradient field across the ventricles was calculated for these low voltages. Ventricular fibrillation was electrically induced, and ventricular activation patterns were recorded after delivering high-voltage shocks just below the defibrillation threshold. With the low-voltage shocks, the potential gradient field was very uneven, with the highest gradient near the epicardial defibrillation electrodes and the weakest gradient distant from the defibrillation electrodes for both RA. V and RV .LV combinations. The mean ratio of the highest to the lowest measured gradient over the entire ventricular epicardium was 19.4 +/- 8.1 SD for the RA. V combination and 14.4 +/- 3.4 for the RV .LV combination. For both defibrillation electrode combinations, the earliest sites of activation after unsuccessful shocks just below the defibrillation threshold were located in areas where the potential gradient was weak for the low-voltage shocks. We conclude that there is a markedly uneven distribution of potential gradients for epicardial defibrillation electrodes with most of the voltage drop occurring near the electrodes, the potential gradient field is significant because it determines where shocks fail to halt fibrillation, and determination of the potential gradient field should lead to the development of improved electrode locations for defibrillation.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom