z-logo
open-access-imgOpen Access
A potential method of correcting intracavitary left ventricular filling pressures for the effects of positive end-expiratory airway pressure.
Author(s) -
Roy V. Ditchey,
JoAnn Lindenfeld,
Eleanor Grogan,
Gary O. Zerbe
Publication year - 1985
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.72.3.660
Subject(s) - preload , medicine , positive end expiratory pressure , cardiology , ventricular pressure , hemodynamics , aortic pressure , anesthesia , intracardiac injection , mechanical ventilation
Based on the observation that positive end-expiratory airway pressure (PEEP) causes comparable increments in intrapericardial and right-sided intracardiac pressures, we hypothesized that intracavitary left ventricular filling pressures measured in the presence of PEEP can be corrected for increased intrathoracic pressure by subtracting the effects of PEEP on intracavitary right ventricular filling pressures. Ventricular function curves (aortic blood flow vs intracavitary left ventricular end-diastolic pressure [LVEDP]) were generated with and without 15 cm of water of PEEP in eight dogs. All curves were shifted to the right by PEEP (i.e., intracavitary LVEDP was higher for any submaximal level of aortic blood flow). However, when pressures measured in the presence of PEEP were "corrected" by subtracting the corresponding increment in intracavitary right ventricular end-diastolic pressure caused by PEEP at each level of ventricular filling, control and corrected PEEP data points appeared to fall on the same curve in five dogs, and differed only slightly in three dogs. Mean control and corrected PEEP curves derived by averaging polynomial regression coefficients for each condition differed significantly from uncorrected PEEP curves (p less than .05), but not from each other. Analogous curves based on mean left atrial pressure were corrected equally well by subtracting the effects of PEEP on mean right atrial pressure. We conclude that the increments in intracavitary right heart filling pressures caused by PEEP can be used to correct intracavitary left heart filling pressures for the effects of PEEP on intrathoracic pressure.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom