Noninvasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach.
Author(s) -
Shinichi Minagoe,
Chuwa Tei,
Akira Kisanuki,
K Arikawa,
Y. Nakazono,
H Yoshimura,
T Kashima,
Hirofumi Tanaka
Publication year - 1985
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.71.4.745
Subject(s) - medicine , parasternal line , shunt (medical) , cardiology , septum secundum , doppler echocardiography , doppler effect , cardiac catheterization , systole , cardiac cycle , diastole , physics , astronomy , blood pressure
Noninvasive pulsed Doppler echocardiography combined with two-dimensional echocardiography by the right parasternal approach was performed to detect the shunt flow through the defect in 31 patients with suspected secundum atrial septal defect (ASD). A defect of the interatrial septum was seen on the two-dimensional echocardiograms of 30 of 31 patients. In all the 30 patients, Doppler signals of shunt flow could be recorded by placing the sample volume in the center of the defect on the two-dimensional echocardiogram. Neither a defect nor Doppler signal indicating shunt flow were demonstrated in any of 15 normal control subjects. Cardiac catheterization indicated significant shunt flow in all the 31 patients with suspected ASD. Doppler signals obtained from the center of the defect showed left-to-right and/or right-to-left shunt flow patterns. The direction of the shunt flow was mainly left to right, with its peak in late systole and atrial systole in 28 of 30 patients; mainly right-to-left flow was present in the remaining two patients, who had Eisenmenger's syndrome. The direction of flow as predicted by the Doppler signal was confirmed by the coincidence of direction of flow as seen on the contrast two-dimensional echocardiogram. In 22 patients for whom the measurement of the pulmonary-to-systemic flow ratio by oximetry was believed to be reasonably accurate, the ratio was fairly well correlated with Doppler-determined left-to-right shunt flow velocity (r = .71, SEE = 6.7 cm/sec).(ABSTRACT TRUNCATED AT 250 WORDS)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom