A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: correlative laboratory and clinical studies.
Author(s) -
Erik J. Meijboom,
S Horowitz,
Lilliam M. ValdesCruz,
David J. Sahn,
D. F. Larson,
Carlos Oliveira Lima
Publication year - 1985
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.71.3.551
Subject(s) - tricuspid valve , medicine , expiration , body orifice , doppler echocardiography , doppler effect , cardiology , diastole , ascending aorta , volume (thermodynamics) , aorta , anatomy , respiratory system , physics , blood pressure , quantum mechanics , astronomy
In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe placed on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a four-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the four-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in four-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and four-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom