z-logo
open-access-imgOpen Access
Validation of quantitation of regional myocardial blood flow in vivo with 11C-labeled human albumin microspheres and positron emission tomography.
Author(s) -
Richard A. Wilson,
Michael J. Shea,
C. De Landsheere,
David R. Turton,
F. Brady,
John Deanfield,
Andrew P. Selwyn
Publication year - 1984
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.70.4.717
Subject(s) - perfusion , albumin , medicine , human serum albumin , positron emission tomography , microsphere , in vivo , nuclear medicine , blood flow , serum albumin , positron , biomedical engineering , chromatography , radiology , chemistry , electron , physics , microbiology and biotechnology , quantum mechanics , chemical engineering , biology , engineering
Use of radiolabeled microspheres is a standard method to measure regional myocardial perfusion in animals. Human albumin microspheres have been given safely to patients, but positron-emitting 68Ga-labeled human albumin microspheres are characterized by an unstable radiolabel. A new labeling procedure that covalently binds 11C (t1/2 = 20.3 min) to human albumin microspheres via 11CH3I was developed. Seven open-chest and two closed-chest dogs were studied. Reference and 11C-labeled human albumin microspheres (2 to 25 mCi) were both injected into the left atrium. Positron tomographic images were obtained of the myocardial distribution of the 11C-labeled microspheres. Timed arterial withdrawal was used for both reference gamma-labeled microspheres and 11C-labeled human albumin microspheres. Myocardial tissue samples matched to tomographic slices were well-counted for calculation of reference values of regional myocardial perfusion. Serial venous blood samples for residual 11C activity of 30 and 60 min after injection were less than 1% of the myocardial 11C concentration demonstrating a stable 11C bond to the human albumin microspheres. Regional myocardial perfusion calculated by this technique correlated well with values obtained with reference microspheres (r = .97) over a range of 0.2 to 3.5 ml/min/g. Correction for wall thickness improved the slope of the regression equation from y = 0.71 x -0.03 to y = 0.88 X -0.05. Thus, 11C human albumin microspheres are stable radiochemically and can be used as a quantitative measure of regional myocardial perfusion.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here