Balloon dilation angioplasty of hypoplastic and stenotic pulmonary arteries.
Author(s) -
James E. Lock,
W R Castańeda-Zúńiga,
Bradley P. Fuhrman,
John L. Bass
Publication year - 1983
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.67.5.962
Subject(s) - medicine , balloon dilation , hypoplasia , cardiology , angioplasty , balloon , stenosis , lung , pulmonary wedge pressure , hilum (anatomy) , pulmonary artery , surgery
Balloon dilation angioplasty (BDA) was attempted in seven children with either stenosis or hypoplasia (a narrowing greater than 1 cm long extending past the lung hilum) of both right and left pulmonary arteries (PAs). In two of these seven, the procedure could not be performed because of technical difficulties. In each of the remaining five children (1 1/2-16 years old), the right ventricular (RV) pressure was greater than 2/3 left ventricular pressure, main PA pressure was greater than 60 mm Hg, and previous operative attempts to relieve RV outflow obstruction, including the branch PA obstruction, were unsuccessful. BDA was performed in only one PA in each patient, and was considered successful if the pressure gradient decreased, angiographic diameter increased and the percentage of blood flow directed to the dilated lung increased. BDA was successful in all five children: RV pressure fell from 104 +/- 42 to 80 +/- 30 mm Hg (p less than 0.05), the gradient across the obstruction fell from 61 +/- 51 to 32 +/- 22 mm Hg (p less than 0.05), the diameter of the narrowed segment increased from 3.7 +/- 1.2 to 6.8 +/- 1.1 mm, p = 0.02), and the percentage of blood flow (as determined by quantitative lung scan) to the dilated lung increased from 41 +/- 16% to 52 +/- 22% (p less than 0.05). No morbidity was observed in any patient. Follow-up angiograms (2-12 months) in three of five patients indicate persistence of the anatomic improvement. While BDA did not restore right-heart pressures and anatomy to normal, it provided significant hemodynamic relief to a group of patients in whom traditional operative management has usually been unsuccessful. Final determination of the role of BDA in such patients must await the results of further studies.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom