z-logo
open-access-imgOpen Access
Aortocoronary saphenous vein bypass grafts. Long-term patency, morphology and blood flow in patients with patent grafts early after surgery.
Author(s) -
Robert I. Hamby,
Agop Aintablian,
Michael Handler,
Choudary Voleti,
Daniel Weisz,
Julius Garvey,
G Wisoff
Publication year - 1979
Publication title -
circulation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 7.795
H-Index - 607
eISSN - 1524-4539
pISSN - 0009-7322
DOI - 10.1161/01.cir.60.4.901
Subject(s) - medicine , coronary artery bypass surgery , artery , cardiology , vein , surgery , coronary artery disease
Early and late (range 5-73 months, average 2.5 years) postoperative arteriographic studies were performed in 85 patients after saphenous vein aortocoronary bypass surgery. In a prior study (⩽ 2 weeks postoperative) of 570 patients with 1197 grafts, arteriography revealed 89.6% early patency of grafts. Late follow-up in 85 patients discharged with all grafts patent revealed 92.2% still patent, an annual mean graft attrition rate (percent of grafts closed/year) of 3.2%/year. This mean graft attrition rate was only slightly affected by regrouping patients according to the interval between the two postoperative studies; however, recurrent angina pectoris was influenced by vein graft attrition. Thus, in 36 patients restudied because of recurrent angina pectoris, the attrition rate was 6.1%/year, compared with 1.1%/year in 49 patients without angina. Progressive coronary artery disease (41% vs 18%), graft closure (22% vs 4%) and incomplete revascularization (39% vs 16%) were significantly more frequent in those with recurrent angina. The frequency of progressive coronary disease was directly related to the duration of follow-up (i.e., the longer the follow-up the higher the frequency of progressive disease). The mean annual rate of progressive coronary disease in arteries not grafted was 11.8%/year. Kinking or graft stenosis was observed in 3.1% of grafts in the early study, while late localized graft narrowing was observed in 8%. At late follow-up, most patent grafts were uniformly narrowed and foreshortened. The mean graft diameter decreased by 17% at late follow-up, and 25% of grafts had at least 25% reduction in mean diameter; however, the mean graft diameter/mean recipient artery diameter ratio exceeded 1.0 in all but one graft. The graft/artery diameter ratio at late follow-up was over 1.5 in 71% of the grafts. The mean graft blood flow determined by cinedensitometric methods revealed a 30% or more reduction in blood flow in 35% of grafts, compared with early postoperative measurements.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom