Endoscopic Management of Colonic Perforation due to Ventriculoperitoneal Shunt: Case Report and Literature Review
Author(s) -
Ana Rita Alves,
Sofia Mendes,
Sandra Lopes,
Alexandre de Almeida Monteiro,
David N. Perdigoto,
Pedro Amaro,
Luís Tomé
Publication year - 2017
Publication title -
ge portuguese journal of gastroenterology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.321
H-Index - 9
eISSN - 2341-4545
pISSN - 2387-1954
DOI - 10.1159/000454987
Subject(s) - medicine , surgery , perforation , asymptomatic , shunt (medical) , catheter , colonoscopy , polypectomy , colorectal cancer , materials science , cancer , punching , metallurgy
The authors report the case of a 41-year-old woman with a colonic perforation due to a ventriculoperitoneal shunt (VPS) catheter. Left-sided colonic perforation was diagnosed by abdominal computed tomography 28 years after shunt placement, following acute meningitis caused by Escherichia coli . The proximal end of the VPS was exteriorized and it was decided to remove the distal end by colonoscopy. After pulling out the catheter with a polypectomy snare, it broke at the site where it was entering the colon, leaving a small perforation in the colonic wall which was closed with 2 endoclips. The endoluminal fragment of the catheter, being 20 cm in length, was removed through the rectum. The patient is asymptomatic at the 12-month follow-up. A review of the literature regarding 9 endoscopically managed cases of digestive tract perforation caused by VPS is presented.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom