Mannheim Carotid Intima-Media Thickness and Plaque Consensus (2004–2006–2011)
Author(s) -
PierreJean Touboul,
Michael G. Hennerici,
Stephen Meairs,
Hadie Adams,
Pierre Amarenco,
Natan M. Bornstein,
László Csiba,
Moı̈se Desvarieux,
Shah Ebrahim,
R. Hernandez Hernandez,
Michael R. Jaff,
Serge Kownator,
Tasneem Z. Naqvi,
Patrizio Prati,
Tatjana Rundek,
Matthias Sitzer,
Ulf Schminke,
JeanClaude Tardif,
Andrew J. Taylor,
Éric Vicaut,
K.S. Woo
Publication year - 2012
Publication title -
cerebrovascular diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.221
H-Index - 104
eISSN - 1421-9786
pISSN - 1015-9770
DOI - 10.1159/000343145
Subject(s) - medicine , intima media thickness , surrogate endpoint , tunica media , randomized controlled trial , lumen (anatomy) , clinical trial , radiology , cardiology , carotid arteries , medical physics
Intima-media thickness (IMT) provides a surrogate end point of cardiovascular outcomes in clinical trials evaluating the efficacy of cardiovascular risk factor modification. Carotid artery plaque further adds to the cardiovascular risk assessment. It is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. The scientific basis for use of IMT in clinical trials and practice includes ultrasound physics, technical and disease-related principles as well as best practice on the performance, interpretation and documentation of study results. Comparison of IMT results obtained from epidemiological and interventional studies around the world relies on harmonization on approaches to carotid image acquisition and analysis. This updated consensus document delineates further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT. Standardized methods will foster homogenous data collection and analysis, improve the power of randomized clinical trials incorporating IMT and plaque measurements and facilitate the merging of large databases for meta-analyses. IMT results are applied to individual patients as an integrated assessment of cardiovascular risk factors. However, this document recommends against serial monitoring in individual patients.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom