Spontaneous Rupture of Peritoneal Catheters
Author(s) -
J. Guiserix
Publication year - 1997
Publication title -
nephron
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.951
H-Index - 72
eISSN - 1423-0186
pISSN - 0028-2766
DOI - 10.1159/000189508
Subject(s) - icon , medicine , citation , world wide web , download , information retrieval , library science , computer science , programming language
Dr. José Guiserix, Centre Hospitalier Général Saint-Pierre-le-Tampon, Service de Médecine F, Néphrologie-Hémodialyse, F97448 Saint-Pierre Cedex, La Réunion (France) Dear Sir, We have been using double-cuff Tenck-hoff catheters for 5 years, manufactured in North America, which were sterilized with ethylene oxide. Our dialysis population amounts to about 30 continuous ambulatory peritoneal dialysis and 5 intermittent dialysis patients. During the past 36 months, we have observed a rise in the frequency of spontaneous ruptures of peritoneal catheters, involving about ten incidents in our centre to this day. In each instance, the catheter was recut and the connection restored. Under systematic 48-hour intraperitoneal cotrimoxazole protection, no peritonitis occurred. The first incidents were considered accidents. The patients underwent thorough interrogation, but no obvious reason was found. The last such incidence occurred in September 1995, the catheter being inserted in February 1994. Rupture, which has up to now only been observed in continuous ambulatory peritoneal dialysis using the UV Flash system, happens each time precisely at the junction between titanium nozzle and catheter, at the radiopaque strip (fig. 1). Puzzled by the increasing number of ruptures, we learned incidentally that iodized disinfectants should not be used in hemodialysis silicone catheters [Sposito, unpubl. data]. Now, we use 10% iodized polyvidone to disinfect the titanium nozzle area every time the extension is replaced, about every other month to up to now. As these devices, the composition of which is not precisely known to us, contain silicone [1], it may be possible that rupture occurs when some chemical weakening caused by interaction with the disinfectant iodine is aggravated by local mechanical strains. The area involved withstands important tractions, torsions, and bending of the line, especially when using the non-disconnect technique where the patients wind their line and the empty bag. The radiopaque strip probably has a weakening effect too. However, since these Fig. 1. Typical location of spontaneous rupture: at radiopaque strip level and the junction between peritoneal catheter and titanium nozzle. Acknowledgement We are indebted to Mr. Miguel Sposito, Laboratoire du Rein Artificiel, Hôpital Necker, Unite Inserm 90, Paris, France, for communication of his unpublished data about hemodialysis silicon tubing and references about silicon incompatibilities. incidents occurred recently, a possible hypothesis is that the composition of the catheters was modified during the past years, possibly involving an increased ratio or another type [2] of silicone. References
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom