J.M. Campistol, MD, Nephrology Service, Hospital Clinic i Provincial, Villarroel, 170, E-08036 Barcelona (Spain) Dear Sir, The subclavian hemodialysis catheter has become a widely used form of temporary vascular access for hemodialysis and plasmapheresis [1, 2]. It is used both for short-term dialysis in cases of acute renal failure, and also for long-term hemodialysis when the permanent vascular access is temporarily nonfunctional [1]. Sporadic reports of subclavian catheter-related complications, such as pulmonary embolism, atrial or caval perforation, air embolism, hydrothorax, hemothorax, infections and thrombosis, have appeared in the literature. Most complications occur within a few days of catheter implantation [2–5]. We report herein a thoracic duct injury with cutaneous lymphatic fistula, related to a subclavian dialysis catheter placement on the left side. This complication has not been previously reported. Case Report A 52-year-old man, on maintenance hemodialysis for chronic glomerulonephritis since 1972, was admitted because of progressive obstruction of a left forearm arteriovenous ñstula created 14 years previously. A hemodialysis subclavian catheter was placed, with some difficulties, in the left subclavian vein. The chest X-ray confirmed its proper position and the absence of complications. The first hemodialysis was performed without any incidences. The next day the patient required a new dialysis session but the catheter did not deliver enough blood flow. The catheter was removed, and immediately a milky fluid sprang under pressure through the puncture hole. The analysis of the fluid revealed: proteins 3.2 g/dl, albumin 1.8 g/dl, glucose 40 mg/dl, sodium 130 mEq/1, potassium 3 mEq/1, total lipids 950 mg/dl, cholesterol 525 mg/dl, and fatty acids 270 mg/dl. Manual pressure was applied over the cutaneous lymphatic leak and a fixed compressive system was placed afterwards. Twenty-four hours later the lymphatic leak ceased and no chylothorax developed. Discussion Advantages of subclavian access for hemodialysis include its ready availability, ease of insertion, the relatively low incidence of complications and the fact that its use avoids sacrificing peripheral vessels as temporary access sites [1, 5]. Potential acute complications of this procedure are air embolism, subclavian artery puncture, atrial or caval perforation, pneumothorax, catheter embolism and thoracic duct injury [2, 7]. Major complications generally have a sudden onset, allowing corrective measures to be rapidly instituted [5]. Verification of

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom