z-logo
open-access-imgOpen Access
Parameters That Influence the Ultrasonic Bond Quality
Author(s) -
P. L. L. M. Derks
Publication year - 1982
Publication title -
active and passive electronic components
Language(s) - English
Resource type - Journals
eISSN - 1026-7034
pISSN - 0882-7516
DOI - 10.1155/apec.10.269
Subject(s) - ultrasonic sensor , bond , quality (philosophy) , materials science , environmental science , acoustics , business , physics , finance , quantum mechanics
This paper summarizes some non-destructive ultrasonic bond quality test methods. Systems described in the literature are mainly based on monitoring the deviation of the vibration amplitude during welding and the correlation between the bond strength with these deviations. Practical application of these principles can give discouraging results. A better understanding of the bond formation process should enable one to understand what causes the amplitude to deviate, and why this is strongly dependent on the ultrasonic bond system involved.