z-logo
open-access-imgOpen Access
Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression
Author(s) -
Mahnaz Arshad,
Amirmohsen Asgari,
M J Kharazifard,
Narges Ameri
Publication year - 2022
Publication title -
international journal of dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.61
H-Index - 33
eISSN - 1687-8736
pISSN - 1687-8728
DOI - 10.1155/2022/8634091
Subject(s) - orthodontics , impression , edentulism , scanner , molar , displacement (psychology) , posterior teeth , dentistry , implant , mathematics , repeated measures design , medicine , biomedical engineering , computer science , statistics , surgery , artificial intelligence , psychology , world wide web , psychotherapist
Objectives. This study aimed to assess the effect of implant angulation on the rotational displacement of a 3-unit bridge following a digital impression. Materials and Methods. This in vitro experimental study evaluated 3 master models of the maxilla with Kennedy’s class III partial edentulism and bilateral three-unit implant-supported fixed partial dentures. Two implants were placed with 0° (first model), 15° (second model), and 30° (third model) interimplant angles. The implants were placed bilaterally at the sites of first premolars and first molars from the posterior towards the anterior region and coded A (posterior) and B (anterior) in the left, and C (posterior) and D (anterior) in the right side. Next, their position was recorded using a coordinate measuring machine to serve as a reference. The models were then scanned by both 3Shape and Sirona digital scanners (12 times by each scanner). The obtained data were compared with the reference data three-dimensionally using GOM Inspect software to determine the rotational displacement of the implants. Data were analyzed by repeated-measures ANOVA, one-way ANOVA, paired sample t-test, and independent sample t-test ( P  < 0.05). Results. Since repeated-measures ANOVA showed that the interaction effect was significant ( P  = 0.010), the data were analyzed by subgroup analysis. The 3Shape scanner showed significantly higher accuracy for C-D region in model 2 ( P  = 0.001), and A-B region in model 1 ( P  ≤ 0.01). In the use of the 3Shape scanner, model 3 showed a lower error rate in the A-B region, compared with models 1 and 2. Model 1 showed higher error rate than models 2 and 3 in the C-D region ( P  ≤ 0.01). In the use of the Sirona scanner, model 1 showed a higher error rate than models 2 ( P  = 0.031) and 3 ( P  = 0.004) in the C-D region. Conclusion. In digital impressions of angulated implants in 3-unit bridges by using 3Shape and Sirona scanners, the rotational error decreases as the interimplant angle increases.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom