z-logo
open-access-imgOpen Access
Extended Use of The Spanner® Temporary Prostatic Stent in Catheter-Dependent Men with Comorbidities
Author(s) -
Angelo Cambio,
Richard M. Roach,
Paul Arnold,
Joseph Cambio,
Clifford Gluck,
Sean Heron
Publication year - 2022
Publication title -
advances in urology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.18
H-Index - 30
eISSN - 1687-6377
pISSN - 1687-6369
DOI - 10.1155/2022/7367851
Subject(s) - medicine , adverse effect , catheter , urinary catheterization , overactive bladder , international prostate symptom score , urinary retention , bacteriuria , foley catheter , urology , urinary system , anesthesia , prostate , surgery , lower urinary tract symptoms , alternative medicine , pathology , cancer
Purpose. This US FDA investigational device exemption (IDE) study evaluated the extended use of The Spanner® Temporary Prostatic Stent in catheter-dependent men with urinary retention who were not deemed candidates for corrective surgery but demonstrated bladder contractility. Materials and Methods. The Spanner was placed for 3 cycles of 30 days in catheter-dependent men with comorbid conditions, confirmed detrusor contractility, and catheter-associated discomfort. At each visit, postvoid residual, maximum flow rate, international prostate symptom score, quality of life, and adverse events were assessed. Voiding success was defined as PVR ≤ 150 ml at all visits. Results. One hundred seven men were enrolled at 8 US sites; 82/107 (76.6%) completed the trial, and 79/107 (73.8%) successfully maintained PVR ≤ 150 ml for the trial duration. Patients were 77.1 ± 10.6 years old; 63/107 (58.9%) were dependent on Foley and 40/107 (37.4%) on intermittent catheterization for 36.0 ± 39.3 days and 30.2 ± 45.8 days, respectively. 25/107 (23.4%) discontinuations were primarily due to voluntary patient withdrawal 9/107 (8.4%), investigator-initiated withdrawal 8/107 (7.5%), or lack of effectiveness 4/107 (3.7%). During Spanner use, the mean Qmax was 11.2 ± 6.6, mean IPSS was 7.5 ± 6.4, and mean QOL was 2.0 ± 1.6. The most prevalent device-related adverse events were asymptomatic bacteriuria 25/107 (23.4%), discomfort 10/107 (9.4%), and urinary urgency 8/107 (7.5%). No device-related serious AEs were reported. Conclusions. This study demonstrates that catheter-dependent men with sufficient bladder contractility can achieve volitional voiding and successful bladder drainage using The Spanner Temporary Prostatic Stent for extended periods of time.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom